Introduction: The Collimator design and Optimization are essential in small animal molecular imaging for preclinical studies. In this study, a mathematical model was derived and used to optimize the slit Collimator for small animal imaging applications.  Materials and Methods: The geometric efficiency was formulated as a source-to-detector distance for a certain amount of the Collimator resolution (). The first-order derivative of the derived formula gives the optimized parameters. The detector performance was modeled in terms of intrinsic resolution . Furthermore, the edge penetration effect was considered using the validated model. Results: Optimum source-to-detector distance  was found as . For an ideal detector, optimal, geometric efficiency  and slit aperture width  were found as ,  and , respectively. Where   and  are the source-to-Collimator distance and detector length, respectively. For the fixed resolution of 1.0 mm, the sensitivity for different source-to-Collimator distances of 50.0, 100.0, and 150.0 mm was calculated as, , and , respectively. In addition, for a sub-millimeter resolution of 0.5 mm at 15.0, 30.0, and 50.0 mm, the geometric efficiency was calculated as, , , and . For a typical source-to-Collimator distance (15.0 mm), the optimal geometric efficiencies are, , , , and   for the resolutions of 0.25, 0.50, 1.0, 1.5, and 2.0 mm, respectively. Conclusion: Based on the analytic model predictions, the performance characteristics of the slit Collimator in terms of geometric efficiency and resolution were extracted. The importance of the proposed model lies both in its speed and ease of application.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 17

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2021
  • Volume: 

    18
  • Issue: 

    AB0028
  • Pages: 

    263-269
Measures: 
  • Citations: 

    0
  • Views: 

    36
  • Downloads: 

    17
Abstract: 

Introduction: In yttrium-90 imaging, image quality is highly dependent on the selection of energy window and Collimator design becausetheY-90 bremsstrahlung photons have a continuous and broad energy distribution. The current study aimed to optimize the bremsstrahlung energy window setting and Collimator for the improvement of both resolution and sensitivity. Material and Methods: In the present study, simulation of medical imaging nuclear detectors (SIMIND) Monte Carlo program was used to simulate Siemens Medical System Symbia. The SIMIND was utilized to generate the Y-90 bremsstrahlung single-photon emission computed tomography (SPECT) projection of the point source. Six energy windows settings and two Collimators denoting medium energy and high energy were used in order to assess the effect of the energy window on the resolution. Results: The experimental measurements and simulation results showed a similar pattern in the point spread functions with the energy window. The simulation data indicated that the geometric component reached 73%for the energy window within the range of51-120keVusingthe high-energy (HE) Collimator. In addition, the obtained results showed that the full width at half maximum (FWHM) and full width at tenth maximum (FWTM)(FWHM=7mm and FWTM=35mm)were higher in this window in comparison to those reported for other windows. Conclusion: According to the obtained results of the present study, the optimal energy window for Y-90 bremsstrahlung SPECT imaging was within the range of 51-120 keV. The obtained optimal energy window and optimal HE Collimator had the potential to improve the image resolution and sensitivity of Y-90 SPECT images.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 36

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 17 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Author(s): 

Malekzadeh Etesam

Issue Info: 
  • Year: 

    2023
  • Volume: 

    10
  • Issue: 

    4
  • Pages: 

    433-440
Measures: 
  • Citations: 

    0
  • Views: 

    18
  • Downloads: 

    9
Abstract: 

Purpose: Gamma cameras are one of the most promising technologies for in-vivo range monitoring in proton therapy. Monte Carlo (MC) simulation is a common calculation-based technique to design and optimize gamma cameras. However, it is prohibitively time-consuming. Analytical modeling speeds up the process of finding the optimal design. Materials and Methods: We proposed an analytical method using the efficiency-resolution trade-off for optimizing a knife-edge Collimator based on the range retrieval precision of protons. Monte Carlo simulation was used for validation of obtained Collimator efficiencies. Results: The model predicts that for the optimal range retrieval precision, the ratio of the source-to-detector distance (𝑟,𝑑,) to the source-to-Collimator distance (𝑟,𝑐,) should be ranging from 1. 7 𝑡, 𝑜,1. 9. For a special case, it was found that assuming an ideal detector (𝑅,𝑖,= 0), the falloff retrieval precision is optimal at 𝑟,𝑑,= 2𝑟,𝑐,independent of the Collimator resolution. Moreover, using the optimized camera, the difference between the MC calculated range and the absolute range was 0. 5 cm (the relative error is about 3%). Conclusion: It was found that the Collimator parameters are in good agreement in comparison with that of the MC results reported in the literature. The analytical method studied in this work can be used to design and optimize imaging systems based on KE Collimators in combination with new detectors in a fast and reliable way.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 18

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 9 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Author(s): 

JERAJ M. | ROBAR V.

Issue Info: 
  • Year: 

    2004
  • Volume: 

    38
  • Issue: 

    3
  • Pages: 

    235-240
Measures: 
  • Citations: 

    1
  • Views: 

    67
  • Downloads: 

    0
Keywords: 
Abstract: 

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 67

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Author(s): 

Pourhaji S. | Pourmand A.

Issue Info: 
  • Year: 

    2024
  • Volume: 

    53
  • Issue: 

    4
  • Pages: 

    291-297
Measures: 
  • Citations: 

    0
  • Views: 

    44
  • Downloads: 

    5
Abstract: 

In this paper, recommended spiral passive micromixer was designed and simulated. spiral design has the potential to create and strengthen the centrifugal force and the secondary flow. A series of simulations were carried out to evaluate the effects of channel width, channel depth, the gap between loops, and flowrate on the micromixer performance. These features impact the contact area of the two fluids and ultimately lead to an increment in the quality of the mixture. In this study, for the flow rate of 25 μl/min and molecular diffusion coefficient of 1×10-10 m2/s, mixing efficiency of more than 90% is achieved after 30 (approximately one-third of the total channel length). Finally, the optimized design fabricated using proposed 3D printing method.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 44

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 5 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2008
  • Volume: 

    32
  • Issue: 

    B3
  • Pages: 

    265-277
Measures: 
  • Citations: 

    0
  • Views: 

    847
  • Downloads: 

    162
Abstract: 

Application of the network equivalent concept for external system representation for power system transient analysis is well known. However, the challenge to utilize an equivalent network, approximated by a rational function, is to guarantee the passivity of the corresponding model. In this regard, special techniques are required to enforce the passivity of the equivalent model through a post processing approach that minimizes its impact on the original model characteristics. In this paper, the passivity is enforced by expressing the problem in terms of a convex Optimization problem that guarantees the global optimal solution. The convex Optimization problem is efficiently solved by recently developed numerical interior–point methods. This passivity enforcement is also global which indicates that the passivity enforcement in one region does not lead to passivity violation in other regions.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 847

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 162 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2019
  • Volume: 

    9
  • Issue: 

    2
  • Pages: 

    137-150
Measures: 
  • Citations: 

    0
  • Views: 

    156
  • Downloads: 

    81
Abstract: 

Introduction: This study investigates basic dosimetric properties of unflattened 6 MV photon beam shaped by multileaf Collimator and compares them with those of flattened beams. Materials and Methods: Monte Carlo simulation model using BEAM code was developed for a 6MV photon beam based on Varian Clinic 600 unique performance linac operated with and without a flattening filter in beam line. Dosimetric features including lateral profiles, central axis depth dose, photon and electron spectra were calculated for flattened and unflattened cases, separately. Results: An increase in absolute depth dose with a factor of more than 2. 4 was observed for unflattened beam which was dependent on depth. PDDs values were found to be lower for unflattened beam for all field sizes. Significant decrease in calculated mlc leakage was observed when the flattening filter was removed from the beam line. The total scatter factor, SCP was found to show less variation with field sizes for unflattened beam indicating a decrease in head scatter. The beam profiles for unflattened case are found to have lower relative dose value in comparison with flattened beam near the field edge, and it falls off faster with distance. Conclusion: Our study showed that increase in the dose rate and lower peripheral dose could be considered as realistic advantages for unflattened 6MV photon beams.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 156

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 81 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    2010
  • Volume: 

    6
  • Issue: 

    3-4 (24-25)
  • Pages: 

    1-12
Measures: 
  • Citations: 

    0
  • Views: 

    1558
  • Downloads: 

    0
Abstract: 

Introduction: SPECT is a diagnostic imaging technique the main disadvantage of which is the existence of Poisson noise. So far, different methods have been used by scientists to improve SPECT images. The Wavelet Transform is a new method for de-noising which is widely used for noise reduction and quality enhancement of images. The purpose of this paper is evaluation of noise reduction in SPECT images by wavelet.Material and Methods: To calculate and simulate noise in images, it is common in nuclear medicine to use Monte Carlo techniques. The SIMIND software was used to simulate SPECT images in this research. The simulated and real images formed using the current typical (hexagonal) Collimators were de-noised by different types of wavelets.Results: The best type of wavelet was selected for SPECT images. The results demonstrated that the best type of wavelet in the simulated and real images increased Signal to Noise Ratio (SNR) by 33% and 45% respectively. Also, Coefficient of Variation (CV) decreased by 77% and 71% respectively, while Contrast of Recovery (CR) was reduced by only 4% and 9% respectively.Conclusion: Comparing the results for real SPECT images in this paper with previously acquired results in real PET images, it can be concluded that the images of both nuclear medicine systems using Wavelet Transform differ in SNR and CR by only 5% and 7% respectively, and in CV by about 20%. Therefore, wavelet transform is applicable for nuclear medicine image de-noising.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 1558

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Author(s): 

Journal: 

Environ Proces

Issue Info: 
  • Year: 

    1396
  • Volume: 

    4
  • Issue: 

    3
  • Pages: 

    563-572
Measures: 
  • Citations: 

    1
  • Views: 

    156
  • Downloads: 

    0
Keywords: 
Abstract: 

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 156

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 1 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
Issue Info: 
  • Year: 

    0
  • Volume: 

    1
  • Issue: 

    3
  • Pages: 

    35-47
Measures: 
  • Citations: 

    0
  • Views: 

    4
  • Downloads: 

    0
Abstract: 

با گسترش شبکه های کامپیوتری و رشد روزافزون کاربردهای مبتنی بر اینترنت اشیاء (IoT)، شبکه های حسگر بی سیم (WSN)، و شبکه های پویا مانند MANET، مساله بهینه سازی مسیریابی به یکی از چالش های بنیادین در علوم رایانه و مهندسی شبکه تبدیل شده است. الگوریتم های سنتی همچون دایکسترا و بلمن-فورد اگرچه در محیط های پایدار کارایی نسبی دارند، اما به دلیل محدودیت در سازگاری با تغییرات دینامیک و چندهدفه بودن مسائل جدید، پاسخگوی نیازهای محیط های مدرن نیستند. در این راستا، هدف اصلی این مقاله، بررسی جامع نقش و کارایی الگوریتم فاخته (Cuckoo Optimization Algorithm - COA) به عنوان یک الگوریتم فراابتکاری نوین در بهینه سازی مسیریابی شبکه های کامپیوتری است. الگوریتم فاخته با الهام از رفتار تولیدمثل انگلی پرنده فاخته و سازوکار پرش های Lévy، به عنوان رویکردی ساده اما توانمند به ویژه برای حل مسائل غیرخطی، چندهدفه و پویا معرفی شده است. در این مقاله، ضمن تبیین ساختار، مراحل اجرایی و مزایا و معایب الگوریتم فاخته نسبت به روش های دیگر (مانند PSO، GA و ACO)، به مرور مطالعات میدانی و شبیه سازی های انجام شده در حوزه های WSN، MANET، SDN و IoT پرداخته شده است. نتایج پژوهش های گذشته نشان می دهد استفاده از COA سبب کاهش محسوس مصرف انرژی، بهبود نرخ تحویل بسته و افزایش طول عمر شبکه نسبت به الگوریتم های جایگزین شده است. همچنین، کاربردهای عملی COA در محیط های پویا و دارای تغییرات سریع توپولوژی، قابلیت ها و برتری های بیشتری نسبت به رقبای خود آشکار ساخته است. در ادامه، مقاله با تمرکز بر نتایج مقایسه ای میان COA و دیگر الگوریتم های فراابتکاری، نشان می دهد که الگوریتم فاخته به سبب سادگی ساختار، سرعت همگرایی بالا و توان جستجوی جامع تر، برای کاربردهای شبکه ای خصوصاً در سناریوهای داده محور و نوظهور، انتخاب مناسبی است. با این حال، چالش هایی نظیر نیاز به تنظیم بهینه پارامترها، تطبیق محدود با مسائل گسسته و عدم وجود استانداردسازی جامع نیز شناسایی شده است. بر همین اساس، پیشنهادهای پژوهشی آینده، بهره گیری از ترکیب COA با سایر الگوریتم ها، توسعه نسخه های یادگیری محور و به کارگیری آن در محیط های واقعی و بزرگ مقیاس را مورد تاکید قرار می دهد.

Yearly Impact: مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic Resources

View 4

مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesDownload 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesCitation 0 مرکز اطلاعات علمی Scientific Information Database (SID) - Trusted Source for Research and Academic ResourcesRefrence 0
litScript
telegram sharing button
whatsapp sharing button
linkedin sharing button
twitter sharing button
email sharing button
email sharing button
email sharing button
sharethis sharing button